Skip to content

Electronics

Choosing an oscilloscope: bandwidth, sample rate and memory depth

Three specifications decide whether an oscilloscope shows your signal accurately. Here is how they interact.

OSAKA TOOL Engineering Desk · · 2 min read

Bandwidth

Bandwidth is the frequency at which a sine wave is attenuated by 3 dB. Signals near the bandwidth are already displayed with reduced amplitude. A practical rule is to choose bandwidth of at least five times the highest frequency component of interest.

For digital signals, think in terms of edge speed. System rise time is approximately 0.35 divided by bandwidth: a 100 MHz oscilloscope has a rise time of about 3.5 ns, so it cannot show faster edges faithfully.

Sample rate

Sample rate should be several times the bandwidth to reconstruct waveforms accurately. Check the sample rate when all the channels you need are enabled. Some instruments share converters between channels.

Memory depth

Capture time equals memory depth divided by sample rate. Deep memory lets you capture long serial transactions or power-up sequences while keeping full time resolution.

Probing

The probe is part of the measurement system. Use correctly compensated 10:1 passive probes for general work, short ground connections for fast edges, and differential or isolated inputs for power electronics.

Send a specification. Receive a quotation.